Signed in as:
filler@godaddy.com
Signed in as:
filler@godaddy.com
The RTU Open controller continuously monitors and regulates constant volume rooftop operation with reliability and precision. This advanced controller features a sophisticated, factory-engineered control algorithm that provides optimum performance and energy efficiency.
The RTU Open controller also features plug-and-play connectivity to the Carrier i-Vu Open Control System. The Carrier i-Vu Open Control System combines state-of-the-art Carrier equipment, plug-and-play
controllers, and the powerful, web-based i-Vu user interface to form a cohesive, intuitive, and fully-integrated BACnet® Building Automation System. For added flexibility, the RTU Open controller is capable of stand-alone operation. Or, it can be integrated with any Building Automation System utilizing the BACnet, Modbus, LonWorks*, or N2 protocols.
Universal programmable controller provides auxiliary building control to interface with air handlers, chiller plants, hot water systems, lighting, and other HVAC equipment. 12 Inputs/12 Outputs. The UC Open XP controller provides auxiliary building control to interface with air handlers, chiller plants, hot water systems, lighting, and other HVAC equipment. The UC Open XP’s factory-engineered control programs provide simple building integration for commercial applications with 24 I/O point capability as well as Supporting Snap graphical programming for creating customized control programs. The UC Open XP also provides support for 24 additional I/O points through the use of the UC Open XP IO Expander. When combined, these controllers can support up to 48 total I/O points for even greater flexibility
The VAV Single Duct Zone Controller provides zone level temperature and air quality control for a variety of pressure-independent VAV applications. This advanced controller features an integral actuator for easy installation onto single duct air terminals. It also features native BACnet communications and plug and-play connectivity to the Carrier i-Vu Open Control System. The Carrier i-Vu Open Control System combines state-of-the-art Carrier equipment, plug-and-play controllers, and the powerful, web-based i-Vu user interface to form a cohesive, intuitive, and fully integrated BACnet® Building Automation System.
The Multipurpose Controller Open XP (MPC Open XP - #OPN-MPCXP) provides monitoring and control for a variety of HVAC system applications. The MPC Open XP supports multiple I/O configurations for both common and custom HVAC control and connects to up to 20 field points directly (8 outputs and 12 inputs).
The MPC Open XPIO48 (#OPN-MPCXPIO48) and MPC Open XPIO816 (#OPN-MPCXPIO816) are expanders that connect to the expandable MPC Open XP to increase the number of inputs and outputs. To add inputs or outputs to the MPC Open XP, you can attach up to 3 expanders, using any combination of MPC Open XPIO48 and/or MPC Open XPIO816 expanders connected to the Xnet.
Universal programmable controller provides auxiliary building control to interface with lighting, fans, pumps, and other HVAC equipment. 6 Inputs/ 5 Outputs. Comprehensive library of factory-engineered control programs available, including: Pump Control, Lighting Control, Time Scheduling with/without Override, Analog Temperature Control, Discrete & Permissive Interlock, Discrete Staging Control, OA Conditions, BTU Metering, Fuel Oil Metering, Electric Metering, Gas Metering, and Water Metering. Supports Snap graphical programming for creating customized control programs. Supports Carrier communicating room sensors, which allow for local setpoint adjustment and local overrides
Carrier ChillerVu is a sophisticated, scalable, native BACnet® control solution for chiller plant control and operation. It consists of a dedicated controller and a library of factory-engineered control programs that are specifically designed to cover the most common chiller plant configurations.
Carrier ChillerVu factory-engineered control programs, with “Plug ‘n Play” support for specific Carrier CCN® PIC chillers, are designed to provide efficient, automatic control over all aspects of a chiller plant, coordinating the control of chillers, pumps and towers into a finely tuned, cohesive system. Whether you have 2 or 20 chillers, the system is able to control Carrier 19, 23, or 30 series chillers (air or water-cooled). Carrier ChillerVu also supports integration to chiller plant equipment using BACnet, LonWorks® and Modbus® protocols.
Carrier’s WSHP Open Controller is an integrated component of a Carrier water source heat pump. The WSHP Open controller continuously monitors and regulates water source heat pump operation with reliability and precision. This advanced controller features a sophisticated, factory-engineered control algorithm that provides optimum performance and energy efficiency. The WSHP Open controller also features plug-and-play connectivity to the Carrier i-Vu Open Control System. The Carrier i-Vu Open Control System combines state-of-the-art Carrier equipment, plug-and-play controllers, and the powerful, web-based i-Vu user interface to form a cohesive, intuitive, and fully-integrated BACnet® Building Automation System.
The AppController continuously monitors and regulates equipment operation with reliability and precision. The AppController’s factory engineered control programs provide optimum performance and energy efficiency for fan coil, unit ventilator, water source heat pump, and constant volume AHU operation. Supports Snap graphical programming for creating customized control programs. It also features native BACnet communications and plug-and-play connectivity to the Carrier i-Vu Open Control System. The Carrier i-Vu Open Control System combines state of-the-art Carrier equipment, plug-and-play controllers, and the powerful, web-based i-Vu user interface to form a cohesive, intuitive, and fully-integrated BACnet® Building Automation System.
The i-Vu® XT BACnet Link (part# XT-LB) is a BACnet router that: Provides BACnet routing between any supported BACnet communication types. Runs control programs. Can have two BACnet/IP networks communicating on the Gig-E port. Can serve as a BACnet Broadcast Management Device (BBMD) on each of the BACnet/IP networks. Supports Foreign Device Registration (FDR). Supports DHCP IP addressing. Has built-in network diagnostic capture functionality for troubleshooting. Has network statistics that can be viewed numerically or as trend graphs. Works with the i-Vu® v6.5 or later system with the latest cumulative patch.
Can serve as a gateway that can act as a: Master or slave on a Modbus serial network. Server or client on a Modbus TCP/IP network
You can use the Wireless sensors, ZS sensors, and an Equipment Touch on the same Rnet. The number of sensors you can use on a controller's Rnet depends on how many control programs it can have. If the controller supports:
• Zone sensors that may optionally sense humidity, CO2, VOC, or motion
• Only one control program, the Rnet can consist of:
• Up to 5 ZS sensors
• One Wireless Adapter supporting up to 5 wireless sensors
• One Equipment Touch
NOTE You can have any combination of ZS and wireless sensors, but no more than 5 sensors total.
• Multiple control programs, the Rnet can consist of:
• Up to 15 ZS sensors
• One Wireless Adapter supporting up to 15 wireless sensors
• One Equipment Touch
NOTES:
• You can have any combination of ZS and wireless sensors, but no more than 15 sensors total.
• You can have no more than 5 sensors per control program
The Rnet communicates at a rate of 115 kbps and should be wired in a daisy-chain, star, or hybrid configuration.
NOTE: Use the specified type of wire and cable for maximum signal integrity.
Description: 4 conductor, shielded or unshielded, CMP, plenum rated cable
Conductor: 22 AWG (7x0096) bare copper
Maximum length: 500 feet (152 meters)
Insulation: Low-smoke PVC (or equivalent)
Color Code: Black, white, green, red
Shielding: If shielded, Aluminum/Mylar shield (100% coverage) with TC drain wire
UL temperature rating: 32–167°F (0–75°C)
Voltage: 300 Vac, power limited Listing
UL: NEC CL2P, or better